VENTILATION SYSTEMS |
Tiny
30 is economical and practical solution for a proper management of the environment, at any time throughout the year. Ventilation: Timed Ventilation Heat: enviromental heating. Memory: Through a simple click you can see at anytime the minimum and maximum ambient temperatures even after the lack of power. |
|
______________________ |
________________________________________________________________ |
Tiny
31 is economical and practical solution for a
proper management of the environment, at any time throughout the year. Ventilation: 4 speed with programmable limits. Heat: Enviromental Heating Alarm: Audible alarm minimum and maximum. Settings: Possibility of parameter display in absolute or refers to the set of ventilation Memory: Through a simple click you can check at all times the minimum and the maximum ambient temperature even after the power failure. |
|
______________________ |
________________________________________________________________ |
Tiny
32 Speeds
is economical and practical solution for proper
management of the environment, at any time throughout the year. Ventilation: 4 speed with programmable limits and a timer for changing the air. Heat: heating of the environment in two stages. Cooling: Possibility (with additional module) control of cooling. Alarm: Audible alarm minimum and maximum integrated. Setting: Ability to display parameters in absolute or related to the set of ventilation Memory: Through a simple click you can see at anytime the minimum and maximum ambient temperatures even after the lack of power. |
|
______________________ |
________________________________________________________________ |
Tiny
32 Step
is economical and practical solution for proper
management of the environment, at any time throughout the year. Ventilation: 4 Banks with limits programmable timer to change the air. Heat: heating of the environment in two stages. Cooling:Possibility (with additional module) control of cooling. Alarm: Audible alarm minimum and maximum integrated. Settings: Possibility of parameter display in absolute or refers to the set of ventilation Memory: through a simple click you can check at all times the minimum and the maximum ambient temperature even after the power failure. |
|
______________________ |
________________________________________________________________ |
Tiny
33 6Speedsis economical and practical solution for the proper management of the environment, at any time throughout the year. Ventilation: 6 speed with programmable limits and a timer for changing the air. Heat: heating of the environment in two stages. Cooling: Possibility (with additional module) control of cooling. Alarm: Audible alarm minimum and maximum integrated. Settings: Ability to display parameters in absolute or related to the set of ventilation Memory: Through a simple click you can see at anytime the minimum and maximum ambient temperatures even after the lack of power. |
|
______________________ |
________________________________________________________________ |
Tiny
100 you can manage the environment
breeding in all cycles (winter and summer) with great precision. Ventilation: 5 speed with programmable limits and a timer for changing the air. Heat: 3 different ways to handle the heating environment. Cooling: Cooling Control. Alarm: Audible alarm minimum and maximum integrated, with the possibility connecting telephone dialers or other. Settings: Ability to manage the entire environment through a single setting. Memory: Through a simple click you can see at anytime the minimum and maximum temperatures environment even after the power failure. |
|
______________________ |
________________________________________________________________ |
MAC
5 concretized the possibility
to be able to carry out with precision and reliability the Cooling
a farm. Through the control panel equipped with a display
functional, you can set the data related to ventilation,
to heating, to the cooling air and the alarm
maximum and minimum temperature. Compared to traditional ventilation system,
consisting of the steps of speed, with the microcomputer is MAC5
can not set different ventilation systems: • Proportional speed from 0 to 100% of the power of the extractors. • Automating shutters placed in large diameter pipes. • Air extraction system up to five intervention groups. • Timer with dwell times and speeds of spare programmable. • Changing of the longitudinal cross ventilation during the critical period. • Automatic opening of windows relation to the vacuum created by the extractors. • application a new system that saves fuel during ventilation control with the heating (energy saving). • Association of temperature probes of any function (heating, cooling, alarm etc.). |
|
______________________ |
________________________________________________________________ |
ACCESSORIES | |